Instructions for Use of Graphite Electrodes
1. During transportation, the electrodes must be covered with a rainproof tarpaulin.
2. When transporting and stacking electrodes with a forklift, exercise caution and strictly prohibit any collisions. Load only one layer at a time, ensuring proper balance and alignment to prevent slippage, dropping, or breakage.
3. When using a crane for loading and unloading, a separate wire rope must be used; the steel packing straps of the electrodes shall not be directly hooked.
4. Electrodes should be stored in a clean, dry location; when stacked outdoors, they must be covered with a waterproof tarpaulin, and the stack height should not exceed four layers.
5. Before use, the electrodes should be placed near the electric furnace for drying at a temperature not exceeding 150°C for no less than 24 hours.
6. During use, the electrode must be cut with tools; it must not be pulled apart using a crane.
7. For electrode connection, first thoroughly clean the electrode threads. Screw the coupling into one end of the electrode and the lifting coupling into the other end, taking care not to damage the threads. It is recommended not to install the coupling directly onto an electrode that is already in use on the furnace.
8. It is strictly prohibited to clean the electrode threads with steel wool, metal brushes, or sandpaper; only oil- and water-free compressed air may be used for cleaning.
9. Use a rotatable, flexible hook and place a soft support pad beneath the electrode connector to prevent damage to the threads.
10. Before connecting the electrode, its bore should be thoroughly cleaned with oil- and water-free compressed air.
1l. Use an elastic‑hook hoist to lift the electrode into the furnace, align it with the center, lower it slowly, gently screw it in, and then tighten it securely with a clamp.
12. Use a torque wrench to tighten the fastener to the specified torque; mechanical, hydraulic, or pneumatic tools may be employed to achieve the required torque.
13. Failure to make contact between the two electrode end faces, or excessive contact pressure, will both impair normal operation. Please refer to the torque values specified in the table on the right.
14. The electrode holder must be clamped within the two white warning lines. The contact surface between the holder and the electrode should be cleaned regularly to ensure good electrical contact, and the holder’s cooling water jacket must be kept free of leaks.
15. To prevent electrode breakage, no insulating material blocks shall be loaded into the furnace. The motor’s operating current must comply with the maximum allowable current specified in the instruction manual.
16. To prevent electrode breakage, place large pieces at the bottom and small pieces at the top.
Tags:
Previous item
Next item
Previous:
Contact us now
Click to see more
If you have any questions, our 24/7 customer service is online!
More information
Contact Us
Phone:+86 419 5765111
Phone:+86 15102465333 General Manager Ge
+86 13941925958 Ms. Yang
Email:XS@lnhddt.cn
Address: No. 11 Xingliu Road, Carbon and Steel Deep-Processing Industrial Park, Liaoyang County, Liaoyang City, Liaoning Province
Smart Customer Service
0Sorry, there is currently no content in this section.
You can view other sections.
Business license