Graphite electrodes are high‑temperature, oxidation‑resistant conductive materials produced through a series of processes, including crushing, batching, kneading, molding, baking, impregnation, graphitization, and mechanical machining, using petroleum coke as the aggregate and coal tar pitch as the binder.
Graphite electrodes exhibit excellent electrical properties and chemical stability, high mechanical strength at elevated temperatures, low impurity content, and superior vibration resistance. They are also excellent conductors of both heat and electricity.
Graphite electrodes are essential conductive materials in the electric smelting industry, characterized by excellent electrical and thermal conductivity, high mechanical strength, and superior oxidation‑ and corrosion‑resistance at elevated temperatures. They are widely used in arc steelmaking furnaces, submerged arc furnaces (for producing ferroalloys, elemental silicon, yellow phosphorus, matte copper, calcium carbide, and other products), and resistance furnaces (such as graphitization furnaces for manufacturing graphite electrodes, glass‑melting furnaces, and electric furnaces for producing silicon carbide). As such, they have become an integral component of the modern raw‑materials industry.
Depending on the operating power and current, different raw materials and manufacturing processes are employed, resulting in three main categories: standard‑power graphite electrodes, high‑power graphite electrodes, and ultra‑high‑power graphite electrodes. By electrode diameter, they are available in a range of sizes from φ75 to φ700 mm. Moreover, in response to specific customer requirements, we can fabricate custom‑sized graphite electrodes and specially shaped graphite products.I. Transportation of Graphite Electrodes
1. Graphite electrodes must be covered with a waterproof tarpaulin during long-distance transportation.
2. When using lifting equipment to handle electrodes packaged in wooden crates, wire ropes must be employed; direct hooking onto the electrode’s steel packing straps is prohibited.
3. To protect the electrode end face and threads, do not lift the electrode directly by hooking it into the electrode hole with an iron hook.
4. When handling and loading/unloading the joint boxes, handle them gently to avoid damaging the threads.II. Storage of Graphite Electrodes
1. Electrodes should be stored in a clean, dry environment. For electrodes and connectors that are not currently in use, do not remove the packaging to prevent dust and debris from entering the threads or electrode openings, which could compromise mating accuracy.
2. Electrodes stored in open-air areas must be covered with waterproof tarpaulins.
3. Electrodes stored in the warehouse must be neatly arranged, and pallets on both sides of the stack should be properly supported to prevent the stack from tipping over.
4. The stacking height of bulk electrodes should generally not exceed 2.8 meters, and the number of layers for boxed electrodes should not exceed four.
5. The storage area for joints should not be exposed to excessively high temperatures to prevent the asphalt‑based joint sealant from melting.III. Connection of Graphite Electrodes
1. Electrodes that have been exposed to moisture must be dried before use.
2. Remove the foam plastic protective cap from the spare electrode port and inspect the internal threads for integrity.
3. Clean the surface of the standby electrode and the internal threads of the hole using compressed air that is free of oil and water; avoid using steel wool, metal brushes, or sandpaper for cleaning.
4. Carefully screw the connector into the electrode hole at one end of the spare electrode (it is not recommended to install the connector directly into the electrode that has been removed from the furnace). Avoid striking or damaging the threads.
5. Screw the electrode lifting fixture (graphite is recommended) into the electrode hole at the other end of the spare electrode.
6. When lifting the electrode, place a soft cushion beneath the end of the spare electrode that is fitted with the connector to prevent damage to the connector from impact with the ground. Use the hook to engage the lifting lug of the hoisting device and lift the electrode steadily, ensuring that the electrode does not become loose at the B‑end or collide with other fixed components.
7. Lift the spare electrode above the electrode to be connected, align it with the electrode hole, and lower it slowly. Rotate the spare electrode so that the helical lifting hook turns and descends together with the electrode. When the two electrode end faces are 10–20 mm apart, use compressed air again to clean both electrode end faces and the exposed portions of the connector. During the final lowering of the electrode, avoid abrupt movements; otherwise, severe impact may damage the electrode holes and the threads on the connector.
8. Use a torque wrench to tighten the spare electrode until the end faces of both electrodes are in tight contact (the correct gap between the electrode and the connector should be less than 0.05 mm).IV. Precautions for the Use of Graphite Electrodes
1. The electrode holder should be clamped outside the warning line on the top electrode; otherwise, the electrode may easily break. The contact surface between the holder and the electrode should be cleaned regularly to ensure good electrical contact, and the holder’s cooling water jacket should be kept free of leaks.
2. If gaps are detected at the electrode connections, the cause must be identified and the gaps eliminated before use.
3. During electrode connection, if any connector bolts are found to have come loose, re‑tighten the bolts before proceeding with the connection.
4. The electrodes should be used in a vertical position; avoid tilting during operation. In particular, do not place a set of connected electrodes horizontally to prevent breakage.
5. When charging the electric furnace, large pieces of charge should be placed near the furnace bottom to minimize the impact of falling large chunks on the electrodes.
6. During smelting, avoid piling large quantities of insulating material directly beneath the electrode to prevent adverse effects on electrode performance and potential electrode breakage.
7. When the electrode is being raised or lowered, avoid any contact with the furnace lid to prevent damage to the electrode.
8. At the smelting site, care must be taken to prevent molten slag from splashing onto the electrodes or threaded connections stored on-site, as this can compromise thread accuracy.Product Name: Ultra-High-Power Graphite Electrode
Nominal diameter, mm
Permissible current load, A
Current density, A/cm²
300
15,000–22,000
20–30
350
20,000–30,000
20–30
400
25,000–40,000
19–30
450
32,000–45,000
19–27
500
38,000–55,000
18–27
550
45,000–70,000
18–27
600
50,000–97,000
18–27
650
55,000–110,000
18–27
700
85,000–120,000
18–27
750
90,000–130,000
18–27
800
95,000–140,000
18–27
Product Name: High-Power Graphite Electrode
Nominal diameter, mm
Permissible current load, A
Current density, A/cm²
200
5,500–9,000
18–25
225
6,500–10,000
18–25
250
80,000–13,000
18–25
300
13,000–17,400
17–24
350
17,400–24,000
17–24
400
21,000–31,000
16–24
450
25,000–40,000
15–24
500
30,000–48,000
15–24
550
44,000–58,000
15–24
600
52,000–67,000
15–24
Product Name: Standard-Power Graphite Electrode
Nominal diameter, mm
Permissible current load, A
Current density, A/cm²
200
5,000–6,900
15–21
250
7,000–10,000
14–20
300
10,000–13,000
14–18
350
13,500–18,000
14–18
400
18,000–23,500
14–18
450
22,000–27,000
13–17
500
25,000–32,000
13–16
550
30,000–42,000
13–16
600
40,000–53,000
13–16
SEO:
Precautions for Use
1. Graphite electrodes shall be covered with rain tarpaulins during transportation.
2. Handle and lift electrodes carefully by forklift to avoid collision. Stack only one layer at a time, keep balance and alignment to prevent falling or breakage.
3. Steel wire ropes must be used for crane loading and unloading. Do not lift the steel bands on electrodes directly.
4. Electrodes shall be stored in a clean and dry place. The stacking height shall not exceed four layers. If stacked outdoors in rainy weather, cover them with waterproof tarpaulins.
5. Moist electrodes shall be dried in a drying furnace before use. The temperature shall not exceed 150°C, and the drying time shall be no less than 24 hours.
6. Use special tools to cut steel bands when using electrodes. Do not use a crane for this operation to prevent accidents.
7. Blow clean the electrode end faces and nipple holes before connection. Screw the nipple into one end of the electrode and the lifting nipple into the other end. Do not place the nipple directly on the working electrode in the furnace.
8. Do not use steel wool, metal brushes or abrasive cloth to clean electrode threads. Oil-free and water-free compressed air may be used when necessary.
9. When lifting with an electrode lifting tool, place soft pads at the electrode nipple joint to avoid thread damage.
10. Lift the electrode above the furnace with a lifter equipped with a spiral hook, align it with the center of the nipple hole, lower it slowly, and tighten it into place with the torque ring.
11. Tighten the electrodes with a torque wrench at the proper torque to ensure no obvious gap at the joint between two electrodes.
12. Excessive or insufficient torque will cause adverse effects. Apply torque strictly in accordance with the specified value.
13. The electrode holder must be positioned between the two white safety lines. The contact surface between the holder and electrode shall be cleaned regularly to maintain good contact. The cooling water jacket of the holder shall be fastened tightly to prevent water leakage.
14. Insulating materials shall not be charged into the furnace to avoid electrode breakage. The operating current of the electrode must comply with its allowable current load.
15. When charging scrap steel, place small pieces on top of large pieces to prevent material collapse and electrode breakage.
Production capacity
Frequently Asked Questions
What are the precautions for use?
1. Graphite electrodes shall be covered with rain tarpaulins during transportation. 2. Handle and lift electrodes carefully by forklift to avoid collision. Stack only one layer at a time, keep balance and alignment to prevent falling or breakage. 3. Steel wire ropes must be used for crane loading and unloading. Do not lift the steel bands on electrodes directly. 4. Electrodes shall be stored in a clean and dry place. The stacking height shall not exceed four layers. If stacked outdoors in rainy weather, cover them with waterproof tarpaulins. 5. Moist electrodes shall be dried in a drying furnace before use. The temperature shall not exceed 150°C, and the drying time shall be no less than 24 hours. 6. Use special tools to cut steel bands when using electrodes. Do not use a crane for this operation to prevent accidents. 7. Blow clean the electrode end faces and nipple holes before connection. Screw the nipple into one end of the electrode and the lifting nipple into the other end. Do not place the nipple directly on the working electrode in the furnace. 8. Do not use steel wool, metal brushes or abrasive cloth to clean electrode threads. Oil-free and water-free compressed air may be used when necessary. 9. When lifting with an electrode lifting tool, place soft pads at the electrode nipple joint to avoid thread damage. 10. Lift the electrode above the furnace with a lifter equipped with a spiral hook, align it with the center of the nipple hole, lower it slowly, and tighten it into place with the torque ring. 11. Tighten the electrodes with a torque wrench at the proper torque to ensure no obvious gap at the joint between two electrodes. 12. Excessive or insufficient torque will cause adverse effects. Apply torque strictly in accordance with the specified value. 13. The electrode holder must be positioned between the two white safety lines. The contact surface between the holder and electrode shall be cleaned regularly to maintain good contact. The cooling water jacket of the holder shall be fastened tightly to prevent water leakage. 14. Insulating materials shall not be charged into the furnace to avoid electrode breakage. The operating current of the electrode must comply with its allowable current load. 15. When charging scrap steel, place small pieces on top of large pieces to prevent material collapse and electrode breakage.
What is the level of hardware and production equipment at Liaoning Hongda New Materials Technology Co., Ltd.?
The company is equipped with industry‑leading production facilities, including 24 counterflow calcination furnaces, a 4,100‑ton vertical‑ram horizontal extrusion press, multiple hydraulic presses, a rotary roasting furnace, a tunnel kiln, an internal‑series graphitization furnace, and five CNC‑automated production lines for electrodes and connectors, all supported by advanced information‑based production management to ensure consistent product quality.
What are the geographical advantages of Liaoning Hongda New Materials Technology Co., Ltd.?
The company is located in Liaoyang, Liaoning Province—a central chemical hub in southern Liaoning—bordering Anshan to the south and adjacent to the Liaohe Oilfield to the west. It lies 260 kilometers from Dalian Port and 600 kilometers from Tianjin Port, enjoying favorable transportation links and a strategic industrial location.
What products does Liaoning Hongda New Materials Technology Co., Ltd. primarily manufacture?
The company specializes in graphite electrodes of various specifications, offering products ranging from Φ200 to Φ700 mm—standard‑power graphite electrodes, impregnated (high‑density) graphite electrodes, high‑power graphite electrodes, and ultra‑high‑power graphite electrodes. Annual production capacity reaches 50,000 metric tons.
Related products
Contact Us
Phone:+86 419 5765111
Phone:+86 15102465333 General Manager Ge
+86 13941925958 Ms. Yang
Email:XS@lnhddt.cn
Address: No. 11 Xingliu Road, Carbon and Steel Deep-Processing Industrial Park, Liaoyang County, Liaoyang City, Liaoning Province
Smart Customer Service
0Sorry, there is currently no content in this section.
You can view other sections.
Business license